00002299-01
VSWR Adjustable Waveguide
02200108-01
Air Data Test Set
- Simultaneously measures an input pressure and controls an output pressure
- Displays input and output pressure parameters as steady state altitude or airspeed or as rate of change of altitude or airspeed
- Provides 2 pneumatic outputs (Ps and Pt)
- Altitude can be displayed in feet or meters
- Airspeed can be displayed in knots, MPH, ft/s, m/s, km/Hr, Mach
- Pressure can be programmed or read in inches Hg, PSI, mBar, kPa
- Static pressure (Ps) output has a range of 0 to 32.15 inches HgA
- Total Pressure (Pt) output has a range of -0.5 to 73.55 inches Hg
- Operates in local or remote mode
02200207-10
Compressor/Vacuum Pump Case Assembly
02300521-10
Controller Case Assembly with Controller (BRAT 514A)
- Used to position camera
- Provides power for system
- Provides communication from computer
04000197-10
Switch Assembly
- BRAT universal analog crosspoint switch assembly
05001000-10
Antenna Mass Simulator
- Provides the capability required to test Antenna Servo Electronics systems
08010009-10
Liquid Cooling System
- A liquid cooling cart for use with high power RF systems
- Supplies liquid coolant
- Remote On and Off
- Coolant types: Coolanol 25 or PAO
- Coolant flow of 2.5 gal/min
- Interconnecting hoses and cables
94100500-10
Electronic Power Control Center - BRAT with Rubidium
- Power up sequencing of single-phase/3-phase power input to outlets
- Elapsed time indicator
- Emergency stop for removing power from configured outlets
- Monitoring of AC line inputs for dropout/reversed phases
- Rubidium oscillator with 3 high-isolation outputs for common stable time reference
94100500-30
Electronic Power Control Center - BRAT
- Power up sequencing of single-phase/3-phase power input to outlets
- Elapsed time indicator
- Emergency stop for removing power from configured outlets
- Monitoring of AC line inputs for dropout/reversed phases
94100500-50
Electronic Power Control Center - Single Phase
- Power up sequencing of single-phase power input to outlets
- Elapsed time indicator
- Emergency stop for removing power from configured outlets
94100500-70
Electronic Power Control Center - RF Rack
- Power up sequencing of single-phase power input to outlets
- Elapsed time indicator
- Emergency stop for removing power from configured outlets
94100500-90
Electronic Power Control Center - BRAT with Rubidium
- Power up sequencing of single-phase/3-phase power input to outlets
- Elapsed time indicator
- Emergency stop for removing power from configured outlets
- Monitoring of AC line inputs for dropout/reversed phases
- Rubidium oscillator with 3 high-isolation outputs for common stable time reference
94100500-110
Electronic Power Control Center - BRAT
- Power up sequencing of single-phase/3-phase power input to outlets
- Elapsed time indicator
- Emergency stop for removing power from configured outlets
- Monitoring of AC line inputs for dropout/reversed phases
94100500-130
Electronic Power Control Center - Single Phase
- Power up sequencing of single-phase power input to outlets
- Elapsed time indicator
- Emergency stop for removing power from configured outlets
94100500-150
Electronic Power Control Center - RF Rack
- Power up sequencing of single-phase power input to outlets
- Elapsed time indicator
- Emergency stop for removing power from configured outlets
94100500-190
Electronic Power Control Center - Single Phase with Rubidium
(with Internal Drops)
- Power up sequencing of single-phase power input to outlets
- Elapsed time indicator
- Emergency stop for removing power from configured outlets
- Rubidium oscillator with 3 high-isolation outputs for common stable time reference
94100500-230
Electronic Power Control Center - Single Phase with Rubidium
(with Rear Multi-Coax)
- Power up sequencing of single-phase power input to outlets
- Elapsed time indicator
- Emergency stop for removing power from configured outlets
- Rubidium oscillator with 3 high-isolation outputs for common stable time reference
94100500-250
Electronic Power Control Center - Single Phase with Rubidium
(with Rear Multi-Coax)
- Power up sequencing of single-phase power input to outlets
- Elapsed time indicator
- Emergency stop for removing power from configured outlets
- Rubidium oscillator with 3 high-isolation outputs for common stable time reference
94100604-01
Frequency Counter
- CW and pulsed RF signals to 20 GHz
- Frequency and power of repetitive signals down to 50 ns
- Pulse widths from 50 ns to 1 second
- Pulse periods from 250 ns to 1 second
- Internal or external timing and control signals
94100671-10
Waveguide Pressurization Unit and Blower Assembly
- Super-dried compressed air at 15 psi
- Forced air up to 270 cfm (free delivery)
- Monitored outputs: 3 (blower pressure, blower air flow, compressed air pressure)
94100671-30
Waveguide Pressurization Unit
- Super-dried compressed air at 15 psi
94101013-10
Phase Noise Measurement System Reference Source Unit
- Generates RF reference signals in UHF, L, and X bands
- Coherent UHF, L-band, and X-band outputs from external reference source
- Simultaneous fixed-frequency outputs with individually controlled amplitudes
94101013-50
Phase Noise Measurement System Reference Source Unit with Option 02
- Generates RF reference signals in UHF, L, and X bands
- Coherent UHF, L-band, and X-band outputs from external reference source
- Simultaneous fixed-frequency outputs with individually controlled amplitudes
- Increases the programmable COHO frequency coverage
- Noise source injection testing
- 2-tone RF signal generation
- Increased programmable attenuation
- Increased switching capabilities
94101013-OPT02
Phase Noise Measurement System Reference Source Unit Option 02 - Broadband Upgrade
94101130-01
Phase Noise Measurement System
- Measures phase and amplitude noise on both CW and pulsed RF signals at carrier frequencies between 10 MHz and 18 GHz
- Measures absolute phase noise, additive phase noise, and amplitude phase noise
- Measures noise at any offsets between 0.01 Hz and 40 MHz
94101201-10
Logic Analyzer Case Assembly
- High speed digital logic analyzer for use in analyzing complex digital waveforms
- 102 Channels
- 200 MHz State mode operation
- 800 MHz Timing mode operation
95650142-10
Three-Phase Power Distribution System
- EMI/RFI filter
- 14 Outlets
- Remote power on/off
- Circuit breakers for each phase
- Rack mountable
95650143-10
Single-Phase Power Distribution System
- EMI/RFI filter
- Eight outlets
- Remote power on/off
- Circuit breaker protection
- Rack mountable
96000169-10
1.2 MHz Low Pass Filter Assembly
96000169-30
2.2 MHz Low Pass Filter Assembly
96000170-10
1.9 MHz Low Pass Filter Assembly
98715001-01
DC Power Supply
- Resolution: 12 bits
- Range: 1 x 0 to 600 Vdc @ 1.7 A
98715001-03
DC Power Supply
- Resolution: 12 bits
- Range: 1 x 0 to 60 Vdc @ 16 A
98715002-01
Relay Matrix
- Format: 32 x 8 switched pairs
- Voltage: 200 Vdc max.
- Current: 1.5 A carry, 0.5 A switch
- Bandwidth: 50 MHz
98715003-01
Form C Relays
- Relays: 48 Form C relays
- Voltage: 220 V switch
- Current: 0.5 A switch
- Bandwidth: 50 MHz at -3 dB
- Power: 1.25 KVA max.
98715004-01
Rail Generator for 98715005-01
- Levels: 4 output voltage levels, 4 input voltage levels
- Range: -4 Vdc to +7 Vdc
98715005-01
Programmable Level Dynamic Digital Unit
- Pins: 32 input, 32 output (options for additional pins)
- Skew: 15 ns max.
- Edge: Resolution 100 ps, accy ±2 ns
- Clock: 25 MHz pattern rate, 16 format clocks
- Memory: 7 @ 64K each (output, 3-state, out algorithm, expect, mask, in algorithm, record)
- Levels: Programmable
98715006-01
Variable I/O Module for 98715005-01
- Output drivers: 32 programmable channels
- Input receivers: 32 programmable channels
98715007-01
Static Digital Latch
- Pins: 64 input, 64 output
- Input threshold level: Programmable -32 to +32 V
- Output level: Internal pull up to 5 V or external to +42 V (max.)
- Output sink current: 250 mA
98715008-01
Programmable Resistance Module
- Channels: 1
- Accuracy: 0.1%
- Resolution: 0.1 W
- Range: 0 to 1 MW
98715009-01
Phase Angle Voltmeter
- Bandwidth: 10 Hz to 100 KHz
- Voltage range: 50 mV to 300 V rms
- Resolution: 5 digits
- Accuracy - phase voltage: 0.08% @ 400 Hz
- Accuracy - total voltage: 0.15% @ 400 Hz
- Accuracy - phase angle: 0.10% @ 400 Hz
- Current: 0 to 16 A
98715010-01
Synchro/Resolver Simulator and Indicator
- Channels: 1 simulator, 1 indicator
- Frequency range: 47 Hz to 1 KHz
- Output level: 2.0 to 90.0 V line to line
- Accuracy: 0.003 degree
- Resolution: 0.001 degree
- Rotation rate: 0.0 to 1000 degree/s
98715011-01
Power Digital to Analog Converter
- Channels: 4
- Voltage range: ±4 Vdc or ±(0 to 40) Vdc
- Resolution: 16 bits
- Current: 0 to 300 mA
98715012-01
Arbitrary Waveform Generator
- Channels: 1 output channel
- Frequency range: 1.0 MHz to 25 MHz
- Amplitude (1 MW): 20 mV to 22 V p-p
- Amplitude (50 W): 10 mV to 11 V p-p
- Standard waveforms: 8 (sin, triangle, square, pulse, pos ramp, neg ramp, arbitrary, DC)
- Custom waveforms: 64K points, 12-bit data, 50 MHz data rate
- Modulation modes: 6 (FM, PM, AM, PSK, FSK, PWM)
98715013-01
Dual-Pulse, Arbitrary Function Generator
- Channels: 2 pulse channels, 1 arbitrary channel
- Frequency range: 10 Hz to 50 MHz
- Amplitude (50 Ohm): 5.0 mV p-p to 22.0 V p-p
- Pulse period: 10.0 ns to 1.0 s
- Pulse width: 10.0 ns to 1.0 s
- Pulse delay: 120 ns to 1.0 s
- Rise/fall times: 3.0 ns to 150 ns
- Modes: 6 (normal, trig, delay trig, burst, gated)
98715014-01
Blower Assembly
- Flow rate: 270 CFM @ 0" water, 160 CFM @ 3" water
- Monitored signals: 3 (temp, press, flow rate)
98715015-01
DC Power Supply
- Resolution: 12 bits
- Range: 1 x 0 to 300 Vdc @ 15 A
98715016-01
Power Amplifier
- Channels: 2 channels
- Gain: x 5 fixed
- Frequency range: DC to 18 KHz
- Drive voltage: 65 V p-p
- Drive current: 1 A
- Output power: 100 W
98715016-03
Power Amplifier
- Channels: 2 channels
- Gain: X10 fixed
- Frequency range: DC to 18 KHz
- Drive voltage: 110 V p-p
- Drive current: 0.5 A
- Output power: 100 W
98715017-01
Rack Blower Assembly
- Flow rate: 320 CFM
98715045-01
Blower Assembly
- Forced air up to 270 cfm (free delivery)
DCSS-10
Dual-Channel Satellite Simulator/Converter
- Provides independent uplink and downlink functions between a 70 MHz IF carrier and UHF frequencies
- Synthesized local oscillators allow frequency tuning while providing low group delay and flat frequency response
- Gain and frequency control can be adjusted locally via front panel
- Stand-alone instrument with remote Ethernet programming/control
- Installed in a ruggedized case for lab or field use
LPF-2009090
Low Power Filter Production